Temp: -75°C to +135 °C, heat shrink tube in many sizes and colours
The heat shrink tubes 45545 with shrink ratio 2 to 1 or 3 to 1 are designed for rail applications. These heat shrink tubes are certified by EN-45545-2. Certifications like UL 224, VW-1 and MIL-I-23053/5 allow these tubes to be used in common industrial and military applications too.
Product facts
Specifications
Temperature
| 2 to 1 shrink ratio -- Dimensions in mm |
|||
| Part number | Inside diameter | Wall thickness | |
| as supplied | after heating | after heating (min) | |
| 45545-1.2-colour code-R | 1.2 | 0.6 | 0.41 (+/- 0.1) |
| 45545-1.6-colour code-R | 1.6 | 0.8 | 0.41 (+/- 0.1) |
| 45545-2.4-colour code-R | 2.4 | 1.2 | 0.51 (+/- 0.1) |
| 45545-3.2-colour code-R | 3.2 | 1.6 | 0.51 (+/- 0.1) |
| 45545-4.8-colour code-R | 4.8 | 2.4 | 0.51 (+/- 0.1) |
| 45545-6.4-colour code-R | 6.4 | 3.2 | 0.64 (+/- 0.1) |
| 45545-9.5-colour code-R | 9.5 | 4.8 | 0.64 (+/- 0.1) |
| 45545-12.7-colour code-R | 12.7 | 6.4 | 0.64 (+/- 0.1) |
| 45545-19.1-colour code-R | 19.1 | 9.5 | 0.76 (+/- 0.15) |
| 45545-25.4-colour code-R | 25.4 | 12.7 | 0.89 (+/- 0.15) |
| 45545-32.0-colour code-R | 32 | 15.9 | 0.89 (+/- 0.15) |
| 45545-40.0-colour code-R | 40 | 20.1 | 1.00 (+/- 0.15) |
| 45545-51.0-colour code-R | 51 | 25.4 | 1.15 (+/- 0.15) |
| 45545-80.0-colour code-R | 80 | 40.1 | 1.27 (+/- 0.2) |
| 45545-102.0-colour code-R | 102 | 50.8 | 1.40 (+/- 0.2) |
| 45545-125.0-colour code-R | 125 | 63.5 | 1.40 (+/- 0.25) |
| 3 to 1 shink ratio -- Dimensions in mm |
|||
| Part number | Inside diameter | Wall thickness | |
| as supplied | after heating | after heating (min.) | |
| 45545-1.5/0.5-colour code-R | 1.5 | 0.5 | 0.45 (+/- 0.1) |
| 45545-3/1-colour code-R | 3 | 1 | 0.55 (+/- 0.1) |
| 45545-4.5/1.5-colour code-R | 4.5 | 1.5 | 0.60 (+/- 0.1) |
| 45545-6/2-colour code-R | 6 | 2 | 0.65 (+/- 0.1) |
| 45545-9/3-colour code-R | 9 | 3 | 0.75 (+/- 0.15) |
| 45545-12/4-colour code-R | 12 | 4 | 0.75 (+/- 0.15) |
| 45545-15/5 colour code-R | 15 | 5 | 0.80 (+/- 0.15) |
| 45545-18/6-colour code-R | 18 | 6 | 0.85 (+/- 0.15) |
| 45545-24/8-colour code-R | 24 | 8 | 1.00 (+/- 0.2) |
| 45545-30/10-colour code-R | 30 | 10 | 1.15 (+/- 0.2) |
| 45545-39/13-colour code-R | 39 | 13 | 1.50 (+/- 0.2) |
| 45545-50/16-colour code-R | 50 | 16 | 2.50 (+/- 0.2) |
| 45545-70/23-colour code-R | 70 | 23 | 2.60 (+/- 0.2) |
| 45545-80/26-colour code-R | 80 | 26 | 2.60 (+/- 0.2) |
| 45545-90/30-colour code-R | 90 | 30 | 2.60 (+/- 0.2) |
| 45545-100/33-colour code-R | 100 | 33 | 2.60 (+/- 0.2) |
| Standard colours |
|||||||
| Colour | Clear | Black | Red | Yellow | Green | Blue | White |
| Colour code | X | 0 | 2 | 4 | 5 | 6 | 9 |
| Colours on request |
|||||||
| Colours | Brown | Orange | Violett | Grey | Yellow/Green | ||
| Colour code | 1 | 3 | 7 | 8 | 45 |
| Properties | ||||
| Values | Test Methods | |||
| Physical | Working temperature | -55°C to +135°C | ||
| Flammability, Smoke | Procedure C | VW-1 | UL 224 | |
| & Toxicity | R24 - HL3 | EN 45545-2 | ||
| Longitudinal change | +/- 8% | |||
| Tensile strength | Unaged | ≥ 10.4 MPa | UL 224 | |
| Elongation at break | ≥ 200% | |||
| Tensile strength | Aged 168h at +175°C | ≥ 7.3 MPa | UL 224 | |
| Elongation at break | ≥ 100% | |||
| Heat shock | 4h at +250°C | No cracking | UL 224 | |
| Cold blend | 1h at -55°C | No cracking | UL 224 | |
| Electrical | Dielectric strength | ≥ 19.7 kV/mm | ASTM D 2671 | |
| Dielectric withstand | 60s at 2500V | No Breakdown | UL 224 | |
| Volume resistivity | ≥ 1014 Ω cm | ASTM D 876 | ||
| Chemical | Copper stability | 168h at +175°C | Pass | UL 224 |
| Anti corrosion | 168h at +175°C | Pass | UL 224 | |